All stainless-steel construction, highly accurate, easy installation and trouble-free performancefor inventory management and in-tank leak detection.
Features
									Probe Data
									Leak Test Performance
									Specifications
							Features
					- Accurate – Five-point temperature sensing element provides exact temperature compensation for product volume contraction and expansion, allowing for accurate inventory management and in-tank leak detection
 - Easy-to-Use – Automatically transmits probe profile to SiteSentinel® iSite™ on start-up, eliminating programming errors
 - Installation – Adjustable probe head centering disks provide a tight fit inside risers with diameters ranging from 2″ (5.1 cm) to 4″ (10.2 cm)
 - Compliance – Supports programmable ALD (Automatic Leak Detection) to perform daily, weekly, monthly, and annually required leak tests for 24-hour continuous monthly leak tests (for SiteSentinel® iSite™ only)
 - All stainless steel construction
 - Welded construction – eliminates potential leak points
 - Level 1 probe – one probe for all applications
 - Easy Installation – Fits in a 2-inch to 4-inch (5.1 cm to 10.2 cm) riser
 - Can be multi-dropped – up to four (4) probes connected on a single I.S. channel (SiteSentinel® iSite™/Integra 100™ only)
 - Optional Density Float – provides a measure of all changes in product density within the specified API density range
 
Probe Data
					- Measures product level changes to a resolution of 0.0005″ (0.0127 mm)
 - Measures product temperature changes to a resolution of 0.001º F (0.1º C)
 - Measures water level changes to a resolution of 0.01″ (0.254 mm)
 - Linearity over the entire probe length is ± 0.04″ (1 mm)
 
Leak Test Performance
					EPA Static Leak and Continuous Test Certified
- 0.2 gph (0.76 L/hr) Statistical Leak Detection (SLD) Test Note: Only available in SiteSentinel® iSite™ and SiteSentinel® Integra 100™: 397,000 gallons (1,502,809 liters)/month throughput for single-tank, 2-tank or 3-tank manifold installations; 30,000-gallon (113,562-liter) combined maximum capacity
 - 0.2 gph (0.76 L/hr) Statistical Leak Detection (SLD) Test: 99.1% Pd, 0.9% Pfa
 - Third-party certified to meet US EPA Static Leak Detection requirements in tanks up to 20,000 gallons (76,000 liters)
 - 0.2 gph (0.76 L/hr) Static Leak Test: 98.18% Pd, 1.82% Pfa
 - 0.1 gph (0.38 L/hr) Static Leak Test: 96.5% Pd, 3.5% Pfa
 - 0.2 gph (0.76 L/hr) Automatic Leak Detection (ALD)
 - 0.1 gph (0.38 L/hr) Automatic Leak Detection (ALD)
 
Specifications
					- Type: Magnetostrictive/Float
 - Material: Stainless-Steel Body, Nickel-Coated Brass Cap
 - Location: Hazardous, Class 1, Division 1, Group D
 - Temperature: 5 RTDs
 - Temperature Range:-40º F to 158º F (-40º C to +70º C) At Pi: 1W
 - Data Cable: 1,000 feet (305 m) Belden 88760 500 feet (152 m) maximum Belden 88761
 
								